In today's challenging times companies are faced with the challenge of keeping the quality of the indoor air and comfort of there employees wile reducing utility coasts. Since heating and cooling your business cane cost up to or more than 50% of an average utility bill, it make since to keep up and maintain your older commercial heating and cooling equipment in good working order and peak performance, not only reducing utility bill but extending the life expectancy of your HVAC equipment. Another good Reason to maintain good working equipment is for the indoor air quality and reduces the emission and leakage of Freon and chlorofluorocarbons up to the atmosphere casing the depletion of the ozone layer (greenhouse effect) protect your environment. The reason that happens is because of poorly maintained equipment. U. S. Air conditioning and Heating always finds the best and most economic solutions for a business with ether a good maintenance program that will keep there heating and cooling equipment running at peak preference saving them money. Or if the HVAC equipment is not worth fixing or maintaining because the units are to run down or to old and not worth putting any money in to them. U. S. Air will recommend the best equipment at the best price that will do the best job and do it at 20% to 30% more efficiently then your older equipment.
U. S. Air conditioning and heating always maintain its high level of work ethic professionalism and high standards. Our tech's are N.A.T. E. certified and they will show up on time clean uniformed and treat your business with respect and do a clean and professional job that will meet all codes regulations and standards. |
 |
|
 |
| SPLIT SYSTEMS |
 |
| GEMINIT Split-Systems |
| Condensing Units with Matching Indoor Components |
System Capacity (Tons) |
Refrigerant |
Application |
Outdoor Condensing Unit |
Matching Indoor Components |
6 to 12½ |
Puron (R-410A) |
Single-Circuit,
Scroll |
38AUZ |
40RUA, 40RUS |
6 to 10 |
R-22 |
Single Circuit,
Scroll |
38ARZ |
40RM, 39L, 39M |
10 |
R-22 |
Single Circuit,
Semi-Hermetic |
38ARS |
40RM, 39L, 39M |
10 to 20 |
R-22 |
Dual Circuit,
Scroll |
38ARD |
40RM, 39L, 39M |
12½ to 20 |
R-22 |
Single Circuit,
Semi-Hermetic |
38AKS |
40RM, 39L, 39M |
25 to 50 |
Puron (R-410A) |
Single-Circuit,
Scroll |
38APS |
40RUA, 40RUS |
6 |
R-22 |
Heat Pump |
38AQ |
40RMQ |
7½, 10 |
R-22 |
Heat Pump |
38ARQ |
40RMQ |
15 |
R-22 |
Heat Pump |
38AQS |
40RMQ |
25 to 40 |
R-22 |
Single Circuit |
38AKS |
40RM, 39L, 39M |
20 to 130 |
R-22 |
Single/
Dual Circuit |
38AH |
39L, 39M |
25 to 100 |
Puron (R-410A) |
Dual Circuit, Scroll |
38APD |
40RUA, 40RUS, 39L, 39M |
|
 |
| Other Split-System Components |
Model |
Description |
Application |
Capacity |
39L |
Central Station Air Handler |
Single-Wall |
1,800 to 15,000 CFM |
39M |
Double-Wall |
1,500 to 15,000 CFM |
1,800 to 15,000 CFM |
28CB |
Horizontal Cased DX Coil |
In-duct applications |
7½ to 10 Tons |
28LA |
Upflow DX Coil |
Twinned furnace applications |
7½ to 10 Tons |
10RT |
Remote Chiller Barrel |
- |
7½ to 350 Tons |
|
 |
| ALL CUSTOM DUCT WORK AND FABRICATIONS |
 |
| We specialize in balancing the air flow so every room gets the write amount of air reducing energy use and extending the life of your HVAC system. All custom duct work exposed indoor flex, spiral ducting, rectangular metal ducts, or outdoor exposed ducting. All custom design and fabrications of sheet metal work plenums power damper and air distribution. Diffusers and indoor air quality control. |
 |
| How Does a Mini-Split Work? |
|
| Installing a Ductless Split System will save you money on installation because no duct work is needed. |
 |
| Where Can Mini-Splits Be Used? |
Older homes, Room additions - Garage conversions - New construction homes - Recording studio's - Recitation rooms
Hospitals and medical facilities - Restaurants - Bars - Server and Computer rooms - Schools - Place of worship
Hotels and motels - Apartments and condo's - Car washes - Conference Rooms - Convenience stores
|
|
|
 |
| What is a Mini-Split? |
Like your refrigerator, heat pumps use electricity to pump refrigerant and transfer heat from one space to another. When we transfer heat from within our home to the outdoors, we call it "air conditioning". Conversely, when we transfer heat from the outdoors to within the home, we call it a "heat-pump."
|
|
|
 |
For More Information Contact Us Toll Free At 1.877.872.4777 |
|